Menu (magicolor 5450) Main Unit Field Service
3-58
III
Adjustment/Setting
7.5.10 SUPPLIES
A. REPLACE/TRANS.BELT
B. REPLACE/TRANS.ROLLER
C. REPLACE/FUSER UNIT
Function • Resets the life counter of the Transfer Belt unit.
Use • To be used when the Transfer Belt unit is replaced.
Setting
/procedure
1. Select “SUPPLIES” and press the MENU/SELECT key.
2. Select “REPLACE” and press the MENU/SELECT key.
3. Select “TRANS.BELT” and press the MENU/SELECT key.
4. Select “ON” and press the MENU/SELECT key.
5. Counter reset is set and after completion the screen returns to the default.
• The default setting is “NO.”
YES NO
Function • Resets the life counter of the Transfer Roller.
Use • To be used when the Transfer Roller is replaced.
Setting
/procedure
1. Select “SUPPLIES” and press the MENU/SELECT key.
2. Select “REPLACE” and press the MENU/SELECT key.
3. Select “TRANS.ROLLER” and press the MENU/SELECT key.
4. Select “ON” and press the MENU/SELECT key.
5. Counter reset is set and after completion the screen returns to the default.
• The default setting is “NO.”
YES NO
Function • Resets the life counter of the Fusing unit
Use • To be used when the Fusing unit is replaced.
Setting
/procedure
1. Select “SUPPLIES” and press the MENU/SELECT key.
2. Select “REPLACE” and press the MENU/SELECT key.
3. Select “FUSER UNIT” and press the MENU/SELECT key.
4. Select “ON” and press the MENU/SELECT key.
5. Counter reset is set and after completion the screen returns to the default.
• The default setting is “NO.”
YES NO
5450_E.book_PDF.book 58 ページ 2005年4月12日 火曜日 午後12時54分