Miscellaneous Malfunctions (Only for magicolor 5430 DL/5440 DL) Main Unit Field Service
4-30
IV
Troublshooting
4.3 ERROR AIDC SENSOR
4.4 ERROR COMMUNICATION
Relevant Electrical Parts
AIDC Sensor/Rt (AIDC R)
AIDC Sensor/Lt (AIDC L)
Mechanical Control Board (PWB-A)
Step Action
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the AIDC R connector for proper connec-
tion and correct as necessary.
--
2
Check the AIDC L connector for proper connec-
tion and correct as necessary.
--
3
Check the PWB-A connector for proper connec-
tion and correct as necessary.
--
4 AIDC R sensor check. - -
5 AIDC L sensor check. - -
6 Change PWB-A. - -
Relevant Electrical Parts
Print Control Board (PWB-P)
Step Action
WIRING DIAGRAM
Control Signal
Location
(Electrical
Component)
1
Check the Ethernet or USB cable for proper con-
nection and correct as necessary.
--
2
Check the PWB-P connector for proper connec-
tion and correct as necessary.
--
3 Change PWB-P. - -
5450_E.book_PDF.book 30 ページ 2005年4月12日 火曜日 午後12時54分