Seitenansicht 60
Firmware Upgrade Main Unit Field Service
2-24
II Maintenance
6. Wait until all of the data is sent.
While the data is being sent, “FIRMWARE UPDATE” and “PROCESSING” are alter-
nately displayed on the screen.
NOTE
NEVER turn the printer Power Switch OFF and ON while data is being sent.
7. After the data has finished being sent, the message “REBOOTING” appears in the con-
trol panel message display and the printer restarts.
8. After the printer has restarted, check that a “READY” message is displayed.
9. From the Menu, select PRINT MENU CONFIGURATION PG and execute the func-
tion. Then, check that the firmware [2] has been upgraded.
For how to execute “CONFIGURATION PG,” see “III Adjustment/Setting.
B. How to upgrade using the Parallel Interface
1. Connect the machine to the PC using a parallel cable.
NOTE
Check that printing is available through the parallel cable.
2. Copy the firmware data and upgrading program to any directory on the PC.
3. Start the Command Prompt and go to the directory in which the firmware data is
stored.
4. Execute the following command to start the transfer of the firmware data to the printer.
(The screen shown below indicates that the firmware data resides on the C drive.)
[2]
4138F2E005DA
PRINTER INFORMATION
DATE
TIME
CONTROLLER F/W
ENGINE F/W
BOOT F/W
TOTAL PAGE COUNT
SERIAL NUMBER
MM.DD.YYYY
HH.MM
413830F0120000(US)
413850G5110000(US)
413899F0110000
7
******
Data to be upgraded Command
FW upgraded data > copy /b 4138**********.prn prn
******: File name of FW upgrade data
4138F2E006DA